9920:
Error
occurred
during
model
upgrade
from
a
pSeries
670
(7040
model
671)
to
a
pSeries
690
(7040
model
681).
Actions:
1.
Verify
that
the
system
being
upgraded
is
a
pSeries
670
(7040
model
671).
This
error
will
occur
if
the
system
has
already
been
upgraded.
2.
The
special
model
upgrade
diskette
might
be
damaged.
Obtain
another
model
upgrade
diskette.
3.
The
diskette
drive
in
the
media
subsystem
might
be
damaged.
Replace
it.
4.
Check
for
system
firmware
updates.
Apply
if
available.
5.
Call
service
support.
A205:
Machine
type
and
model
fields
are
not
valid
in
the
VPD
module.
Obtain
a
new
operator
panel.
Do
not
swap
the
old
VPD
module
onto
the
new
operator
panel.
Call
service
support
for
instructions
on
how
to
write
the
machine
type
and
model
into
the
new
VPD
module.
A20B:
Error
requesting
trace
buffer
for
service
processor.
Actions:
1.
Reset
the
service
processor,
if
possible.
2.
Check
for
system
firmware
updates.
Apply
the
updates
if
they
are
available.
A218:
Unknown
return
code
detected.
Actions:
Check
for
system
firmware
updates.
Apply
the
updates
if
they
are
available.
A21A:
Error
allocating
an
internal
service
processor.
Actions:
1.
Reset
the
service
processor,
if
possible.
2.
Check
for
system
firmware
updates.
Apply
the
updates
if
they
are
available.
A800:
This
indicates
an
HMC/service
processor
initialization
failure.
Actions:
1.
Check
for
system
firmware
updates.
2.
Replace
the
primary
I/O
book,
location:
U1.18-P1-H2.
A801:
This
indicates
an
HMC
wrap
failure.
Actions:
Replace
the
primary
I/O
book,
location:
U1.18-P1-H2.
A806:
This
indicates
a
loss
of
the
surveillance
heartbeat
between
the
HMC
and
the
service
processor.
Actions:
1.
Make
sure
that
the
HMC
is
booted
and
operational.
2.
Check
the
serial
cables
that
go
from
the
HMC
to
the
primary
I/O
book,
location:
U1.18-P1-H2.
If
there
are
no
other
error
codes
or
indications
of
a
problem,
the
A806
(loss
of
surveillance
heartbeat)
was
a
temporary
condition
and
has
been
resolved;
the
B1xx4699
code
is
then
an
informational
message
only.
If
the
problem
persists:
1.
Run
diagnostics
on
the
serial
port
on
the
HMC.
2.
Replace
the
primary
I/O
book,
location
U1.18-P1-H2.
Error
Code
B1xx
8FF0
The
following
error
code
was
moved
out
of
the
Common
Firmware
Error
Code
table
because
of
the
size
of
the
description
column.
212
EserverpSeries
615
Service
Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM P 615 series and is the answer not in the manual?

IBM P 615 series Specifications

General IconGeneral
BrandIBM
ModelP 615 series
CategoryServer
LanguageEnglish

Related product manuals