EasyManuals Logo
Home>IBM>Server>P 615 series

IBM P 615 series User Manual

IBM P 615 series
491 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #395 background imageLoading...
Page #395 background image
Chapter
11.
SRNs
for
Linux
The
x
in
the
following
group
of
SRNs
is
encoded
as
follows:
8
4
2
1
|
|
|
|
|
|
|
Replace
all
FRUs
listed
|
|
Hot
swap
supported
|
Software
might
be
the
cause
Reserved
Note:
Some
SRNs
in
this
chapter
may
have
4
rather
than
3
digits
after
the
dash
(-).
Use
the
physical
location
codes
and
FRU
numbers
listed
on
the
diagnostics
Problem
Report
Screen.Failing
Function
Codes
(FFCs)
are
not
used
in
this
group
of
SRNs.
For
more
detailed
information
refer
to
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
Service
Request
Number
Description
and
Action
651-88x
The
CEC
or
SPCN
reported
an
error.
Action:
Refer
to
the
entry
MAP
in
this
system
unit’s
system
service
guide,
with
the
8
digit
error
and
location
codes,
for
the
necessary
repair
action.
If
the
8
digit
error
and
location
codes
were
NOT
reported,
then
call
support.
651-89x
The
CEC
or
SPCN
reported
an
error.
Action:
Refer
to
the
entry
MAP
in
this
system
unit’s
system
service
guide,
with
the
8
digit
error
and
location
codes,
for
the
necessary
repair
action.
If
the
8
digit
error
and
location
codes
were
NOT
reported,
then
call
support.
652-88x
The
CEC
or
SPCN
reported
a
non-critical
error.
Action:
Schedule
deferred
maintenance.
Refer
to
the
entry
MAP
in
this
system
unit’s
system
service
guide,
with
the
8
digit
error
and
location
codes,
for
the
necessary
repair
action.
If
the
8
digit
error
and
location
codes
were
NOT
reported,
then
call
support.
652-89x
The
CEC
or
SPCN
reported
a
non-critical
error.
Action:
Schedule
deferred
maintenance.
Refer
to
the
entry
MAP
in
this
system
unit’s
system
service
guide,
with
the
8
digit
error
and
location
codes,
for
the
necessary
repair
action.
If
the
8
digit
error
and
location
codes
were
NOT
reported,
then
call
support.
A00-FF0
Description:
Error
log
analysis
is
unable
to
determine
the
error.
The
error
log
indicates
the
following
physical
FRU
locations
as
the
probable
causes.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A01-00x
Description:
Error
log
analysis
indicates
an
error
detected
by
the
CPU,
but
the
failure
could
not
be
isolated.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A01-01x
Description:
CPU
internal
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A01-02x
Description:
CPU
internal
cache
or
cache
controller
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A01-03x
Description:
External
cache
parity
or
multi-bit
ECC
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A01-04x
Description:
External
cache
ECC
single-bit
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A01-05x
Description:
System
bus
time-out
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A01-06x
Description:
Time-out
error
waiting
for
I/O.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
375

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM P 615 series and is the answer not in the manual?

IBM P 615 series Specifications

General IconGeneral
BrandIBM
ModelP 615 series
CategoryServer
LanguageEnglish

Related product manuals