Model
6C3
Removal
and
Installation
into
a
Rack
Before
performing
these
procedures,
read
“Safety
Notices”
on
page
xi.
System
Drawer
Removal
CAUTION:
This
unit
weighs
between
32
kg
(70.5
pounds)
and
55
kg
(121.2
pounds).
Three
persons
are
required
to
safely
move
it.
Using
fewer
than
three
persons
to
move
it
can
result
in
injury.
CAUTION:
v
Removing
the
system
drawer
requires
three
people.
v
Do
not
place
more
than
one
drawer
in
the
service
position
at
one
time.
v
Ensure
that
the
system
cables
are
not
tangled
and
will
not
bind
when
placing
the
system
drawer
into
the
service
or
operating
positions.
To
remove
the
system
drawer
from
the
rack,
do
the
following:
1.
If
you
have
not
already
done
so,
shut
down
the
system
as
described
in
“Stopping
the
System”
on
page
282.
2.
Open
the
front
and
rear
rack
doors.
3.
Disconnect
all
cables
from
the
rear
of
the
system
drawer.
4.
Disconnect
the
cable-management
arm
by
pulling
out
the
two
captive
snap
buttons
from
the
rear
of
the
system
drawer.
5.
From
the
front
of
the
system
drawer,
lift
the
lower
section
of
the
system
drawer
release
latches,
which
are
located
on
each
side
of
the
system
drawer.
The
system
drawer
release
latch
clicks
as
it
is
put
into
the
release
position.
6.
Grasp
the
top
section
of
both
latches,
and
slowly
pull
the
system
drawer
out
into
the
service
position.
7.
Depress
both
safety
release
tabs
located
on
each
inner
rail,
and
pull
the
system
drawer
out
approximately
2
inches.
8.
Put
the
system
drawer
into
the
service
position.
9.
Using
three
persons,
grasp
the
system
drawer
handles
located
on
each
side
of
the
system.
10.
Depress
the
safety
latches
located
on
each
rail.
11.
Remove
the
system
by
pulling
it
completely
out
and
away
from
the
rack
and
outer
rack
rails.
12.
Push
the
extended
outer
rails
carefully
back
into
the
rack.
Note:
There
is
a
gravity-activated
locking
tab
at
the
back
of
each
extended
outer
rail.
The
locking
tab
locks
the
outer
rails
into
their
fully
extended
position
and
is
unlocked
by
the
action
of
the
inner
rail
being
pushed
back
into
the
rack.
To
compensate
for
the
separation
of
the
inner
rail
from
the
outer
rail,
center
the
lock
tab
with
your
hand,
then
push
the
outer
rail
back
into
its
retracted
position.
13.
Close
the
front
and
rear
rack
doors.
Installing
the
Model
6C3
into
the
Rack
Enclosure
CAUTION:
When
installing
this
system
drawer
into
a
rack,
ensure
that
a
hazardous
condition
is
not
created
due
to
uneven
mechanical
loading.
If
your
rack
uses
a
stabilizer
bar,
it
must
be
firmly
attached
before
installing
or
removing
this
system.
To
install
the
Model
6C3
onto
a
system
rail
assembly
(type
2),
do
the
following:
414
EserverpSeries
615
Service
Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM P 615 series and is the answer not in the manual?

IBM P 615 series Specifications

General IconGeneral
BrandIBM
ModelP 615 series
CategoryServer
LanguageEnglish

Related product manuals