Page #398 background image
Service
Request
Number
Description
and
Action
A05-05x
Description:
Sensor
indicates
an
abnormally
high
internal
temperature.
Action:
Verify
that:
1.
The
room
ambient
temperature
is
within
the
system
operating
environment.
2.
There
is
unrestricted
air
flow
around
the
system.
3.
All
system
covers
are
closed.
4.
There
are
no
fan
failures.
If
none
of
these
problems
exist,
then
proceed
with
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-06x
Description:
System
shutdown
due
to
abnormally
high
internal
temperature.
Action:
Verify
that:
1.
The
room
ambient
temperature
is
within
the
system
operating
environment.
2.
There
is
unrestricted
air
flow
around
the
system.
3.
All
system
covers
are
closed.
4.
There
are
no
fan
failures.
If
none
of
these
problems
exist,
then
proceed
with
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-07x
Description:
Sensor
indicates
a
power
supply
has
failed.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-08x
Description:
System
shutdown
due
to
power
supply
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-09x
Description:
Sensor
detected
a
FRU
that
has
failed.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-10x
Description:
System
shutdown
due
to
FRU
that
has
failed.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-14x
Description:
System
shutdown
due
to
power
fault
with
an
unspecified
cause.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-16x
Description:
System
shutdown
due
to
internal
power
supply
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-19x
Description:
System
shutdown
due
to
Fan
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-21x
Description:
System
shutdown
due
to
Over
temperature
condition.
Action:
Verify
the
following:
v
The
room
ambient
temperature
is
within
the
system
operating
environment.
v
There
is
unrestricted
air
flow
around
the
system.
v
All
system
covers
are
closed.
If
all
conditions
are
met,
then
use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-22x
Description:
System
shutdown
due
to
over
temperature
and
fan
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-24x
Description:
Power
Fault
specifically
due
to
internal
battery
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-00x
Description:
Error
log
analysis
indicates
an
error
detected
by
the
Service
Processor,
but
the
failure
could
not
be
isolated.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
378
EserverpSeries
615
Service
Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM P 615 series and is the answer not in the manual?

IBM P 615 series Specifications

General IconGeneral
BrandIBM
ModelP 615 series
CategoryServer
LanguageEnglish

Related product manuals