6. Carefully pull the expansion canister out of the chassis and place it on a safe,
level surface.
Replace the expansion canister
7. To reinstall an expansion canister, or replace it with one from FRU stock, follow
the procedure in “Installing or replacing an expansion canister: 2076-92F” on
page 57.
Removing a fan module: 2076-92F
You can remove a faulty fan module from a 2076-92F expansion enclosure.
Before you begin
Important: You can remove a fan module without powering off the expansion
enclosure. However, to maintain operating temperature, do not remove more than
one fan module at a time.
v Remove a faulty fan module only when its replacement is ready to be installed.
v Do not remove a fan module from an operational enclosure for more than
approximately 10 minutes. The reduction in airflow through the enclosure might
cause the enclosure or its components to shut down to protect from overheating.
About this task
Note: If you plan to remove the expansion enclosure from the rack, you must
remove all of the fan modules.
Procedure
1. Identify the fan module to be replaced. When lit, the amber LED on the front of
the fan module (1 in Figure 100 on page 112) identifies a fault.
svc01015
Figure 99. Removing the expansion canister
Chapter 2. Installing the Storwize V7000 Gen2 and Storwize V7000 Gen2+ hardware 111

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM StorVize V7000 Gen2 and is the answer not in the manual?

IBM StorVize V7000 Gen2 Specifications

General IconGeneral
BrandIBM
ModelStorVize V7000 Gen2
CategoryStorage
LanguageEnglish

Related product manuals