68
5
MENU SCREEN
2001 NEW 2001 NEW
Scan Set mode
Type
(Default: Call)
Set the scan type to “Call,” “S-Meter,” “Voice” or “All
Memory.” (Default: Call)
CALL: Call Scan. It scans the channels that
belong to the network group whose
scan type is “Call.”
If your station ID is called with a Sel-
call or ALE call, the scan stops on that
channel and the voice squelch control
function is activated.
S-Meter: S-Meter Scan. It scans the chan-
nels that belong to the network group
whose scan type is “S-Meter.”
If the transceiver detects a signal
whose S-meter level is higher than the
Meter Squelch Level setting, the scan
stops on that channel.
Voice: Voice Scan. It scans the channels that
belong to the network group whose
scan type is “Voice.”
If the transceiver detects voice compo-
nents, the scan stops on that channel.
All Memory: All Memory Scan. It scans all memory
channels.
If the transceiver detects a signal
whose S-meter level is higher than the
Meter Squelch Level setting, the scan
stops on that channel.
Voice Scan Resume
(Default: 10sec)
Set the scan resume function to ON or OFF for an S-
Meter, Voice or All Memory scan, and set the pause
timer to between 5 seconds and 120 seconds, in 5
second steps. (Default: 10sec)
When this setting is ON and a signal is detected, a
scan pauses for this set period, then resumes, or re-
sumes 2 seconds after the signal disappears.
If OFF is selected, the scan pauses until the signal
disappears.
All Memory Scan Speed
(Default: HIGH)
Set the scan speed for the All Memory scan to LOW,
MID or HIGH. (Default: HIGH)
D Setmode (Continued)