Quick Reference
• On: Turn the sense function on.
Bleeder
Set the Bleeder circuit state (When testing the battery, the user
need to turn the Bleeder circuit off)
• On: Turn the Bleeder circuit on.
• Off: Turn the Bleeder circuit off.
Trig Source Set the trigger source
Keypad
Keypad trigger, [Shift]+[On/Off]
(Trigger)
Bus
Remote interface trigger command,
like *TRG
Ext
External trigger, when the TRIG± inter-
face state is set to IN and receive a
high pulse signal, the instrument gen-
erates trigger.
1.7.2 System Menu Reference
Press [Shift]+[Display] (System) to enter into the system menu interface.
System System Menu
Beep Set the key beeper state.
Off
Turn the key beeper off.
On
Turn the key beeper on.
PowerOn
Select the power-on state.
Reset
When the power supply is powered on, the power supply will
initialize some settings and output state.
Last
When the power supply is powered on, the power supply will
remain the same settings and output state as last time you
turned off the power supply.
Last+Off
When the power supply is powered on, the power supply will
remain the same settings as last time you turned off the power
supply, but the output state is OFF state.
Connect
Set the working mode of the two channels of the instrument.
Single
Configure the instrument to 2-channel independent output
mode.
Parallel
Configure the instrument to 2-channel parallel mode.
Series
Configure the instrument to 2-channel series mode.
It is forbidden to output more than 100V voltage after two
channels are connected in series.