Functions and Features
4.7.4 Run List Program
The user can run the existed list program as needed to enable outputting of cor-
responding waveform sequence by the power supply. Detailed operation steps
are as below:
1. Press [Shift]+[I-set] (Function) to enter function menu interface.
2. Use left and right keys or rotate the knob to select List and press [Enter]
key to enter the set interface of list mode.
3. Select the desired list program.
Method 1: Select Recall List and press [Enter] key. Use knob to select
the desired list program and press [Enter] key to confirm.
Method 2: To simplify the operation, you can directly run the list program
after editing it in the Edit List menu item. Skip the step in the Recall List
menu item.
4. Select Run List and press [Enter] key to confirm.
5. Use the knob to set Run List to On and press [Enter] key to confirm.
6. Press [On/Off] key to turn the output on.
7. Based on the trigger method, perform the trigger operation. When the trigger
signal is received, the power supply outputs the waveform sequences.
Stop running: During the running of List, you can press [Shift]+[I-set] (Func-
tion) to enter the Function menu and set the Run List as Off to stop running.
Otherwise, the List waveform cannot be edited while the List is running.
4.8 External Analog Function (Option)
This menu item is used to control the external analog function to enable or dis-
able. The external analog interface is not the standard-equipped interface for
the power supply.
This series power supply provides a optional DB–25 analog interface(IT-
E1208). The analog interface provides the following capability:
Remote control of output voltage and current
Remote control of output On/Off state
Remote monitoring of output voltage/current measurement and CC/CV
mode
Remote monitoring of output On/Off state, load status and fault status
Clear the instrument malfunction
RS-485 communication interface, please refer to 2.7.6 RS-485 Interface for
detailed description about the interface
Copyright © Itech Electronic Co., Ltd.
74

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3131D and is the answer not in the manual?

ITech IT-M3131D Specifications

General IconGeneral
BrandITech
ModelIT-M3131D
CategoryPower Supply
LanguageEnglish

Related product manuals