Functions and Features
4.4 Channel Parallel Function (Parallel)
Parallel in the System menu supports connect the two channels of a single IT-
M3100D in parallel, the upper limit of the current setting range is twice the rated
value of the single channel, and the instrument is used as a single channel
power supply at this time.
Parallel configuration of 2 or more IT-M3100Ds is not supported.
After parallel combination, it is operated as a single instrument. The initial set-
tings of each function menu and voltage, current and power are based on the
following rules:
Config menu: After Parallel, the CC/CV priority, on/off delay, Sense switch,
and trigger mode in the Config menu refer to the settings of CH1, and the
rise/fall time in the Config menu refers to the slowest slope setting of the two
channels. After switching back to single, both channels refer to Parallel
settings.
Voltage/Current/Power setting: After Parallel, V-set is the smaller value of
the two-channel voltage. I-set is the sum of the current settings of the two
channels. P-set is twice the power set value of CH1. When switching back to
single, the current and power setting values of the two channels are half of
the corresponding setting of Parallel, and the voltage is the corresponding
voltage in Parallel mode.
PROTECT menu: After Parallel, the default is the parameters of CH1 chan-
nel. When switching back to single, the two channels are Parallel
parameters.
OPP: After Parallel, the setting value is the sum of the OPP setting values of
the two channels. When switching back to single, it is half of Parallel OPP.
OCP: After Parallel, OCP defaults to the sum of the OCP current settings of
the two channels. When switching back to single, the OCP of the two chan-
nels is half of Parallel.
Foldback protection: When the Foldback settings of the two channels are
the same, after combining, the default is the setting of CH1. When the Fold-
back settings of the two channels are different, the Foldback will be turned
off after Parallel. When switching back to single, the settings of the two chan-
nels are the same as those of Parallel.
Save/Recall: When it is Single, after the two channels execute save and
Parallel respectively, the recall voltage value is the CH1 voltage value, and
the current is the sum of the current values of the two channels. When it is
Copyright © Itech Electronic Co., Ltd.
60

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3131D and is the answer not in the manual?

ITech IT-M3131D Specifications

General IconGeneral
BrandITech
ModelIT-M3131D
CategoryPower Supply
LanguageEnglish

Related product manuals