Inspection and Installation
connected to the output terminals. This is referred to as Local measurement. If
you need to use remote sensing, after making the connection, be sure to turn
the sense function on. Please refer to 4.2.3 Set the Sense Function State for
the detailed operations.
Precautions
To prevent electric shock and damage to the instrument, observe the following
precautions.
Before connecting test cables, be sure to switch off the power sup-
ply. Power switch is in Off position, otherwise touching the output
terminals on the rear panel may result in personal injury or death
due to electric shock.
To avoid electrical shock, before testing, please make sure the rat-
ing values of the testing cables, and do not measure the current
that higher than the rating value. All test cables shall be capable of
withstanding the maximum short circuit output current of the
power supply without causing overheat.
If several loads are provided, each pair of load wires shall safely
withstand the rated short circuit output current of the power supply
under full load.
To avoid battery short circuit, be sure to check that the test line end
is not connected when connecting or disassembling the test line.
When the test line end is connected with battery, short circuit may
cause severe accident.
Please check that the test cables can withstand maximum current
During wiring, check that the anode and cathode of the test lines
are properly and tightly connected; anode ON and cathode OFF are
prohibited.
If you need to pull out the green output terminal, please lift it up
and pull it out, otherwise it will damage the instrument.
Specification
Test cables are not standard accessories for the instrument. Please select op-
tional red and black test cables for individual sales based on the maximum cur-
rent value. For specifications of test cables and maximum current values, refer
to A.1 AppendixSpecifications of Red and Black Test Lines for more
information.
Copyright © Itech Electronic Co., Ltd.
21

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3140 Series and is the answer not in the manual?

ITech IT-M3140 Series Specifications

General IconGeneral
BrandITech
ModelIT-M3140 Series
CategoryPower Supply
LanguageEnglish

Related product manuals