Basic Operations
Copyright © ITECH Electronic Co., Ltd. 24
Chapter3 Basic Operations
This chapter describes operations of the keys on the front panel of the
electronic load. The electronic load must be in the local mode when controlled
by the front panel. The default mode is the local mode after the electronic load
is turned on. In the local mode, the user can enable all functions of the load
through the front panel.
3.1 Input On/Off Control
[On]/[Off] button on the front panel are used to control input switch. [On] button
lighted indicates the load input is on and the [Off] button lighted indicates the
load input is off. The initial state of electronic load is OFF.
3.2 Key Lock Function
Press [Lock] key to lock the front panel keys, LOCK label will display in LCD
screen. In this condition, the other keys are invalid except Lock key. Press
[Lock] key again to unlock.
3.3 Menu Configuration Function
System configuration such as the load mode and general settings are set in the
load menu. Press “MENU” on the front panel to set the system menu. You can
set the following menu items.
Menu
Menu Setting
SYSTEM
SYSTEM INFO
Instrument system
information
Model
Instrument model
Serial
Instrument SN
Cpu Version
The version of Cpu
Dsp Version
The version of Dsp
Fpga Version
The version of Fpga
MAC address
Network hardware address
Socket Port
Port number
SYSTEM SETUP
System setup
Mode select
AC/DC mode selection
CF/PF setting
CF/PF setting: CF/PF/BOTH
CF/PF Priority
CF/PF setting priority: CF/PF
Timing Mode
Timing mode enabling/disabling: Off/ On
Short Function
Short-circuit function enabling/disabling
(Disable/ Enable), only for the load with DC
mode
Harmonic Formula
Harmonic formula: THDF/ THDR
Peak Hold Mode
Peak holding mode: Off/ On
Power On Setting
Power-on status: SAV0/RST
If Rst is selected, factory settings are
recovered after each start-up
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com

Table of Contents

Other manuals for ITech IT8600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8600 Series and is the answer not in the manual?

ITech IT8600 Series Specifications

General IconGeneral
BrandITech
ModelIT8600 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals