Maintenance
Electrical System
Figure 108.
4. Apply a thin layer of petroleum jelly to the terminal posts.
Hazardous Voltage Batteries
The batteries do not require any regular operator cleaning maintenance.
Connect
12V Battery
WARNING Keep metal watch straps and any metal fasteners on your clothes, clear of the positive (+)
battery terminal. Such items can short between the terminal and nearby metal work. If it happens you can
get burned.
CAUTION The machine is negatively earthed. Always connect the negative pole of the battery to earth.
When connecting the battery, connect the earth (-) lead last.
When disconnecting the battery, disconnect the earth (-) lead first.
CAUTION Understand the electrical circuit before connecting or disconnecting an electrical component. A
wrong connection can cause injury and/or damage.
1. Get access to the battery.
Refer to: Battery Cover (Page 119).
2. Connect the battery leads. Connect the earth (-) terminal last.
3. If the machine has a service disconnect, move the switch to the on position.
Refer to: Service Disconnect (Page 30).
Disconnect
12V Battery
WARNING Keep metal watch straps and any metal fasteners on your clothes, clear of the positive (+)
battery terminal. Such items can short between the terminal and nearby metal work. If it happens you can
get burned.
CAUTION The machine is negatively earthed. Always connect the negative pole of the battery to earth.
When connecting the battery, connect the earth (-) lead last.
When disconnecting the battery, disconnect the earth (-) lead first.
CAUTION Understand the electrical circuit before connecting or disconnecting an electrical component. A
wrong connection can cause injury and/or damage.
Notice: Do not disconnect the battery when the machine is operating, this may cause damage to the
machine electrics.
142 9831/8250-4 142
JCB © Admin Pimteam - 23/06/2021 05:32.

Table of Contents

Other manuals for jcb 19C-1E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jcb 19C-1E and is the answer not in the manual?

jcb 19C-1E Specifications

General IconGeneral
Battery TypeManganese laminated Lithium-ion
Battery Rated Capacity14.8 kWh (3 Pack) 19.8 kWh (4 Pack)
ChargingOn-board charger with direct connection from AC mains power supply
Charging Time110V – 12 hrs 230V – 8 hrs
Fast Charging (Optional)Off-board charger, with connection to 415V 3-Phase supply Charging time <2 hrs
System Voltage48V
Motor TypeAC permanent magnet
Motor Power7 kW continuous 20kW peak
Operating ModesL – 1200rpm G – 1600rpm H – 1800rpm Auto Kick Up – 2300rpm, 2 speed tracking only
Thermal LimitationsOperation: -10oC to +46oC Charging: -10oC to +40oC