(2) Adjusting the height of the needle bar
1) Loosen needle bar connection screw
󰿿
and move the needle bar
󱀀
up or down so that second en-
graved marker line
󱤨
as counted from the bottom is aligned with the bottom end of needlebar bushing
󱀁
when turning the hand pulley to bring the needle bar to its lowest position. Then further raise only
the needle bar by 4.3mm, and tighten needle bar connection screw
󰿿
.
2) Attach the needle (TQx3 #14).
4.3mm
󰿿
󱀀
󱀁
󱤨
(3) Adjusting the feed plate base
󰿿
󱀀
Center
WARNING :
Turn OFF the power before starting the work so as to prevent accidents caused by abrupt start of the
sewing machine.
WARNING :
Turn OFF the power before starting the work so as to prevent accidents caused by abrupt start of the
sewing machine.
Adjust so that the slot of feed plate
󰿿
becomes the center of the boss section of the needle hole guide,
and tighten setscrew
󱀀
.
When the sewing state between the button and the material is loose, replace feed plate
󰿿
with
the feed plate B to obtain a stronger sewing state. At this time, however, the outside diameter of
the button is limited to max. ø19. So, be careful.

Table of Contents

Other manuals for JUKI LK-1900B series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JUKI LK-1900B series and is the answer not in the manual?

JUKI LK-1900B series Specifications

General IconGeneral
BrandJUKI
ModelLK-1900B series
CategorySewing Machine
LanguageEnglish

Related product manuals