9.2 Technical data of COMBIVERT drive converters
OMBIVERT F5 drive converter precharging by AIC at an ambient temperature Ta = 45°C
and UN_max = 440V. Corresponding higher charging currents are expected at higher
mains voltages. In this case please contact KEB!
Size
Housing
PN IN Cint
Load-shunt Max.
charging
currentR Type
400V kW A uF Ω – A
5 B 0.37 1.3 180 33 NTC 19
7 B 0.75 2.6 180 33 NTC 19
9 B 1.5 4.1 300 33 NTC 19
10 B 2.2 5.8 345 10 NTC 62
12 B 4 9.5 470 10 NTC 62
7 D 0.75 2.6 180 33 NTC 19
9 D 1.5 4.1 300 10 NTC 62
10 D 2.2 5.8 345 10 NTC 62
12 D 4 9.5 470 10 NTC 62
13 D 5.5 12 580 10 NTC 62
14 D 7.5 16.5 650 10 NTC 62
12 E 4 9.5 470 20 NTC 31
13 E 5.5 12 580 20 NTC 31
14 E 7.5 16.5 650 20 NTC 31
15 E 11 24 940 20 NTC 31
16 E 15 33 1290 20 NTC 31
14 G 7.5 16.5 650 10 – 62
15 G 11 24 940 10 – 62
16 G 15 33 1290 10 – 62
17 G 18.5 42 1640 10 – 62
18 G 22 50 1875 6 – 104
16 H 15 33 1290 20 – 31
17 H 18.5 42 1640 20 – 31
18 H 22 50 1875 20 – 31
19 H 30 60 2700 20 – 31
20 H 37 75 3900 20 – 31
18 R 22 50 1875 5.0 – –
19 R 30 60 2700 5.0 – –
20 R 37 75 3900 5.0 – –
continued on the next page
59
DIMENSIONING