Section 5: SCPI command reference Model 2231A Triple-channel DC Power Supply Reference Manual
5-6 077100401/September 2014
*PSC
This command is to set and query the power on status flag that controls the automatic power on status of SRER
and ESER.
Item Description
Group SOURCE
Syntax *PSC
*PSC?
Related Commands
APPly subsystem
The commands in this subsystem set voltage and current levels.
[SOURce:]APPLy
This command is to select channels and set voltage and current levels with a single command.
Item Description
Group Apply
Syntax [SOURce:]APPLy {CH1|CH2|CH3},{voltage|Max|Min|Def|Up|Down},
{current|Max|Min|Def|Up|Down}
[SOURce:]APPLy?
Arguments Arg1: CH1|CH2|CH3
Optional Arg2: voltage|Max|Min|Def|Up|Down
Optional Arg3: current|Max|Min|Def|Up|Down
Returns Arg1,Arg2,Arg3
Examples Appl ch1,max,min
[SOURce:]APPly:VOLTage[:LEVel][:IMMediate][:AMPLitude]
This command is to set voltage to all channels at the same time.
Item Description
Group Source
Syntax [SOURce:]APPly:VOLTage[:LEVel][:IMMediate][:AMPLitude]
[SOURce:]APPly:VOLTage[:LEVel][:IMMediate][:AMPLitude]?
Arguments Arg1: voltage setting for CH1
Optional Arg2: voltage setting for CH2
Optional Arg3: voltage setting for CH3