113
114
10
- 56 -
FUEL SYSTEM
Injection pump delivery check on test bench
1 Deliverycontrolrackrod
2Rackrod1 instopposition
3Rackrod1inmax.deliveryposition
A=18-19mm(max.rackrodstroke)
α=66°
Static injection timing
Disconnectpipe1frominjectionpumpandcloseit,toavoidfuellea-
kages.
Mountinitsplaceanylonpipe2asshowninthepicture.Insertinthis
pipeanironwireandletitprojectbyapproximately10mm:inthisway
anydropinfuelcaneasilybechecked.
KD 225_315_350_400_440 Workshop Manual_cod. ED0053029330_1° ed_ rev.00