Repair Service and Repair Manual
Exhaust gas system
3.8 Exhaust gas system
3.8.1 Admission pipes to turbocharger removal and installation
Previous tasks
q Disconnect admission connection of application set.
Specific safety instructions
NOTICE
Risk of property damage by reuse of sealing.
Leakage by faulty seal.
u Replace all sealings.
Special tools
Not applicable.
Consumables and equipment
– Rags
– Cleaner
154
© 2021 by Kohler Co. All rights reserved.
KD62V12 33525088601_7_1 EN_US