EasyManuals Logo
Home>Kohler>Engine>KD83V16

Kohler KD83V16 User Manual

Kohler KD83V16
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
Operation and Maintenance Manual Transportation - Storage
Suspension of activity
3.6 Suspension of activity
The measures set herein are used for protection against engine corrosion damages when
suspended for up to 12 months.
Divergent measures must be coordinated with Kohler Co.
The Diesel engine is installed.
u Fill with operating fluids until it reaches the maximum level. (For more information see:
5.11.2 Filling volume, page 121) .
Information
u The Diesel engine and components delivered are immediately ready for use and do not require
depreservation.
u In an environment-friendly manner, reuse the packaging to send back the engine or other
components.
u Clean the engine and remove the existing rust.
u Spray or apply on unpainted bare parts or surfaces, corrosion inhibitor “Rustilio DWX 30”.
Information
u Do not spray the corrosion inhibitor on electrical connections.
u Follow the procedure for the suspension of activity in the generator set manual.
For starting after 12 months of suspension of activity,
u Follow starting procedure (For more information see: 4.2.9 Initial starting/test run/after out of
service period, page 69) .
KD83V16 33521030601_0_1 EN_US
2018-07
© 2018 by Kohler Co. All rights reserved.
63

Table of Contents

Other manuals for Kohler KD83V16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KD83V16 and is the answer not in the manual?

Kohler KD83V16 Specifications

General IconGeneral
BrandKohler
ModelKD83V16
CategoryEngine
LanguageEnglish

Related product manuals