Operation and Maintenance Manual Control and operation
Starting the engine
4.2.2 Starting in cold temperatures
WARNING
Hazards by use of starting aids containing ether!
Using starting aids containing ether could cause serious injury or death by inhalation of toxic gazes.
u Do not use starting aids containing ether.
The KOHLER generators are equipped with a preheating system.
Fig. 45: Precautions at cold temperatures
The following precautions improve the starting performance at low temperatures. Precautions:
u Check battery charging.
u Recharge battery if required.
u Use Diesel fuel with sufficient flow properties.
4.2.3 Monitoring the running engine
DANGER
Hazards by rotating or moving and ejected parts!
Impacts by ejected parts will cause serious injury or death.
Before monitoring or accessing the engine covers, housing or compartement:
u Switch off the engine. (For more information see: Shutting down the Diesel engine, page 69) .
u Make sure all parts are stopped.
u Secure all parts against unexpected movements.
Engine is under load at rated speed
To ensure Diesel engine performance and endurance, fulfill the following tasks when operating the
machinery:
u Check for leaks.
u Check for unusual noises and vibrations
Troubleshooting
In case of any abnomalies
u Report and rectify immediately by authorized personnel
KD83V16 33521030601_0_1 EN_US
2018-07
© 2018 by Kohler Co. All rights reserved.
67

Table of Contents

Other manuals for Kohler KD83V16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KD83V16 and is the answer not in the manual?

Kohler KD83V16 Specifications

General IconGeneral
BrandKohler
ModelKD83V16
CategoryEngine
LanguageEnglish

Related product manuals