METHOD FOR LUBRICATING EQUALIZER BAR SIDE PIN
(1 place each on right and left sides)
1.
Remove all soil and sand from the top of the track frame
and top of the cover.
2.
Clean the grease fitting shown by arrow.
3.
Supply grease by using a grease pump.
REMARK
• Supply 3 shots of grease (Operate the grease pump
lever 3 times) to each grease fitting, and check that
grease is newly discharged through the seal lip.
• If grease is not newly discharged through the lip por-
tion, continue supplying grease until it is discharged.
•
If the blade is lowered to raise the idler 1 to 2 cm (0.4
to 0.8 in) from the ground in order when performing lu-
brication, the grease will fill the whole circumference
of the pin.
METHOD FOR LUBRICATING EQUALIZER BAR CENTER PIN
(1 place)
1.
Open the engine side cover on the left side of the machine.
2.
Clean the grease fitting shown by arrow.
3.
Supply grease by using a grease pump.
REMARK
If the blade is lowered to raise the idler 1 to 2 cm (0.4 to
0.8 in) from the ground in order when performing lubrica-
tion, the grease will fill the whole circumference of the pin.
MAINTENANCE PROCEDURE MAINTENANCE
4-56