REMARK
If the purified water is added to above the bottom of sleeve (4), use a syringe to remove electrolyte to the bot-
tom of sleeve (4). Neutralize the removed fluid with baking soda (sodium bicarbonate), then flush it away with a
large amount of water. If necessary, consult your Komatsu distributor or a battery manufacturer.
METHOD FOR CHECKING ELECTROLYTE LEVEL ON INDICATOR ETC
If it is possible to use an indicator to check the electrolyte level, follow the instructions given.
METHOD FOR CHECKING AND CLEANING ADDITIONAL FUEL STRAINER
1.
Open cover (1).
2.
Turn fuel supply valve (2) to CLOSE position (C).
3.
Remove strainer cap (3).
The strainer forms one unit with strainer cap (3).
4.
Remove all dirt from the strainer, then wash it in clean die-
sel fuel or flushing oil.
If the strainer is damaged, replace it.
5.
Install the strainer.
6.
Tighten strainer cap (3).
7.
Turn fuel supply valve (2) to OPEN position (O).
MAINTENANCE PROCEDURE MAINTENANCE
4-60