OPERATION OPERATION
3-93
7. When the engine rotation stabilizes, return to the low idle (MIN) position of fuel control dial (1) and then carry
out the warming-up operation.
REMARK
Regardless of the ambient temperature, if the key in starting
switch (2) is turned from OFF position to left, preheating pilot
lamp (3) will light up and preheating will start. (Preheating con-
tinues while the starting switch is held at the left.)
For the details of the preheating time, see the table in Step 5.
While preheating is being carried out, the preheating pilot lamp
(3) lights up to show that preheating is being carried out.
If the engine does not start with the above operation, wait for
about 2 minutes, and repeat steps 3. And 4.