ATTACHMENTS, OPTIONS
HANDLING TORQUE CONVERTER LOCK-UP
WARNING/LIMIT FUNCTIONS FOR TRAVEL SPEED
TRAVEL SPEED WARNING FUNCTION
(This functions even when the torque converter lock-up switch is OFF.)
When the travel speed goes above 40.0 km/h (24.9 MPH) {36.5 km/h (22.7 MPH)}, the central warning lamp lights
up and the alarm buzzer sounds.
At the same time, "OVERRUN PROTECT" is displayed on the character display.
If the alarm buzzer sounds, depress the brake immediately to slow the machine down.
When the travel speed goes below 39.5 km/h (24.5 MPH) {36.0 km/h (22.4)}, the alarm buzzer stops.
TRAVEL SPEED LIMIT FUNCTION
(This functions only when the torque converter lock-up switch is ON.)
To prevent the travel speed from going above 40.0 km/h (24.9 MPH) {36.5 km/h (22.7 MPH)}, the lock-up is
automatically canceled.
The lock-up cancel continues until the travel speed goes below 38.0 km/h {23.6 MPH} [35.0 km/h {21.7 MPH}].
6 - 6