2-66
16. TROUBLESHOOTING 16. TROUBLESHOOTING
16.3 IF BATTERY IS DISCHARGED
WARNING
When checking or handling the battery, stop the engine and
turn the starting switch key to the OFF position before
starting.
Before starting the engine, use a damp cloth to wipe off the
dust accumulated on the top surface of the battery.
The battery generates hydrogen gas, so there is danger of
explosion. Do not bring lighted cigarettes near the battery, or
do anything that will cause sparks.
Battery electrolyte is dilute sulphuric acid, and it will attack
your clothes and skin. If it gets on your clothes or on your
skin, wash it immediately off with large amounts of water. If
it gets in your eyes, wash it out with fresh water, and consult
a doctor.
When handling battery, always wear protective goggles.
When removing the battery, first disconnect the cable from
the ground (normally, from the negative . terminal). When
installing, install the positive + terminal first. If a tool touches
the cable connecting the positive terminal and the chassis,
there is danger that it will cause sparks.
If the terminals are loose, there is danger that the defective
contact may generate sparks that will cause an explosion.
When installing the terminals, install them tightly.
When removing or installing, check which is the positive +
terminal and negative . terminal.
16.3.1 REMOVAL AND INSTALLATION OF BATTERY
When starting the engine with a booster cable, do as follows:
When removing battery, first disconnect the cable from the
ground (normally, from the negative . terminal). If a tool
touches a cable connecting the positive terminal and the chassis,
there is danger of sparks being emitted.
When installing battery, the ground cable should be connected
to the ground terminal as the last step.
When
removing,
disconnect
the cable
from the
ground
terminal first.
When
installing,
connect
the cable to
the positive
+ terminal
first.
w
q
AE072981
AE072980
q
w