33PERIODIC SERVICE
ENGLISH
1. To slow charge the battery, connect the battery
positive terminal to the charger positive terminal and
the negative to the negative, then charge for at least 1
hour at 4.5 amperes.
2. A boost charge is only for emergencies. It will partially
charge the battery at a high rate and in a short time.
When using a boost-charged battery, it is necessary to
recharge the battery as early as possible.
Failure to do this will shorten the battery's service life.
3. When the specific gravity of electrolyte is between
1.27 and 1.29 the charging is completed.
C Battery for storage
1. When storing the machine for a long period, remove
the battery from machine, adjust the electrolyte to the
proper level and store in a dry place out of direct
sunlight.
2. The battery self-discharges while it is stored.
Recharge it once every 3 months in hot seasons and
once every 6 months in cold seasons.
BCleaning Air Cleaner Element
1. The air cleaner uses a dry element, never apply oil.
2. Do not touch the filter element except where cleaning
is required. To clean the element, use clean and dry
compressed air on the inside of the element. Air
pressure should not exceed 205 kPa (2.1kgf/cm ).
A Operating in dusty conditions requires frequent
maintenance.
(1) Battery
(2) Ground cable
(+): Positive terminal
(-): Negative terminal
(1) Air cleaner cover
(2) Air cleaner element