U641 Comm Time 2
Description
Sets the time-out time for fax transmission.
Purpose
To improve transmission performance for international communications mainly.
Method
1. Press the start key.
2. Select the item to be set.
Display Description
T0 TIME OUT Sets the T0 time-out time.
T1 TIME OUT Sets the T1 time-out time.
T2 TIME OUT Sets the T2 time-out time.
Ta TIME OUT Sets the Ta time-out time.
Tb1 TIME OUT Sets the Tb1 time-out time.
Tb2 TIME OUT Sets the Tb2 time-out time.
Tc TIME OUT Sets the Tc time-out time.
Td TIME OUT Sets the Td time-out time.
Setting: T0 time out
Sets the time before detecting a CED or DIS signal after a dialing signal is sent.
Depending on the quality of the exchange, or when the auto select function is selected at the des-
tination unit, a line can be disconnected. Change the setting to prevent this problem.
1. Change the setting using the cursor right/left keys.
Description Setting range Initial setting
T0 time-out time 30 to 90 s 56
2. Press the start key. The value is set.
Setting: T1 time out
Sets the time before receiving the correct signal after call reception. No change is necessary for
this maintenance item.
1. Change the setting using the cursor right/left keys.
Description Setting range Initial setting
T1 time-out time 30 to 90 s 36
2. Press the start key. The value is set.