2NM/2NX/2NY/2NZ/2P0/2P6-1
1-3-44
U252 Set Dest
Description
Switches the operations and screens of the machine according to the destination.
Purpose
To be executed after initializing the backup RAM, in order to return the setting to the value before
replacement or initialization.
Method
1. Press the start key.
2. Select the destination.
Display Description
(No Action) -
Inch Inch (North America) specifications.
Europe Metric Metric (Europe) specifications.
Asia Pacific Metric (Asia Pacific) specifications.
Australia Australia specifications.
China China specifications.
Korea Korea specifications.
3. Press the start key.
4. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
* : An error code is displayed in case of an initialization error.
When errors occurred, turn main power switch off then on, and execute initialization using
maintenance item U252.
Error codes
Display Description
0001 Controller (Entity Error)
0002 Controller (Counter Error)
0020 Engine
0040 Scanner