2NM/2NX/2NY/2NZ/2P0/2P6
1-3-39
U203 Chk DP Ope
Description
Simulates the original conveying operation separately in the DP.
Purpose
To check the DP operation.
Method
1. Press the start key.
2. Place an original in the DP if running this simulation with paper.
3. Select the speed to be operated.
Display Description
Normal Speed Normal reading
High Speed High-speed reading
4. Select the item to be operated.
Display Description
CCD ADP(Non-P) Without paper, single-sided original of CCD
(continuous operation)
CCD ADP With paper, single-sided original of CCD
CCD RADP(Non-P) Without paper, double-sided original of CCD
(continuous operation)
CCD RADP With paper, double-sided original of CCD
5. Press the start key. The operation starts.
6. To stop continuous operation, press the stop key.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.