8: Channel Mode: Channel Configuration
XPress™ DR Industrial Device Server User Guide 56
Send Characters
You can enter up to two characters in hexadecimal representation in the parameters "sendchar."
If a character received on the serial line matches one of these characters, it is sent immediately,
along with any awaiting characters, to the TCP connection. This minimizes the response time for
specific protocol characters on the serial line (for example, ETX, EOT, etc.). Setting the first
sendchar to 00 disables the recognition of the characters. Alternatively, the two characters can be
interpreted as a sequence.
SendChar 1 (00) ? _
SendChar 2 (00) ? _
Telnet Terminal Type
This parameter appears only if the terminal type option is enabled in Disconnect Mode (see
DisConnMode above). If this option is enabled, you can use the terminal name for the Telnet
terminal type. Enter only one name.
Terminal name () ?
If the terminal type option is enabled, the unit also reacts to the EOR (end of record) and binary
options, which can be used for applications like terminal emulation to IBM hosts.
Channel (Port) Password
This parameter appears only if the channel (port) password option is enabled in Disconnect Mode
(see DisConnMode). If set, you can set a password on the serial port.