9: Setup Mode: Advanced Settings
XPress™ DR Industrial Device Server User Guide 60
Disable Web Setup
The Y (Yes) option disables configuration using the Web-Manager. This setting defaults to the N
(No) option.
Disable Web Setup (N) ? _
Disable ECHO Ports
Controls whether the serial port will echo characters it receives.
Disable ECHO ports (Y) ?
Enable Enhanced Password
The Enhanced Password setting allows you to set a password of up to 16 characters for
protecting Telnet and Web Page access. We recommend that you select the Y (Yes) option and
enable the enhanced password setting.
Avoid using either the 4 character basic password setting or no password at all as they are not
secure options.
Enable Enhanced Password (N) ?
Default Settings (Option 7)
Select 7 to reset the unit’s Channel 1 and Enhanced Security to the factory default settings. The
server configurations (IP address information) remain unchanged.
Exit Configuration Mode (Option 8 or Option 9)
Select 8 to exit the configuration mode without saving any changes or rebooting. Select 9 to save
all changes and reboot the device. All values are stored in nonvolatile memory.