BLOWER/WATTS DATA
G43UF−24B−045−1, −3 PERFORMANCE
External
Air Volume / Watts at Different Blower Speeds
tatic
Pressure
High
Medium Low
in.
w.g.
Pa cfm
L/s Watts
cf
m
L/s Watts
cf
m
L/s Watts
0.00
0 975 460 380 870 410 340 720 340 285
0.10 25 935 440 365 855 400 335 710 335 280
0.20 50 910
430 360 830 390 325 680 320 270
0.30
75 870 410 345 795 375 310 655 310 260
0.40 100 825 390 330 760 360 300 630 295 255
0.50 125 760
360 315 715 335 285 610 290 250
0.60
150 725 340 310 675 320 280 580 275 235
0.70 175 680 320 295 630 300 265 545 260 230
0.80 200 620
290 285 575 270 255 495 235 220
0.90
225 555 260 270 520 245 245 425 200 205
G43UF−24B−070−1, −3 PERFORMANCE
External
Air Volume / Watts at Different Blower Speeds
tatic
Pressure
High
Medium Low
in.
w.g.
Pa cfm
L/s Watts cfm L/s Watts cfm L/s Watts
0.00
25 1020 480 380 905 430 345 740 350 280
0.10 25 985 465 370 890 420 330 730 345 270
0.20 50 945
445 355 860 405 325 705 330 265
0.30
75 905 430 345 830 390 315 690 325 260
0.40 100 860 405 330 790 370 300 660 310 250
0.50 125 810
380 320 750 355 290 630 300 240
0.60
150 740 350 305 710 335 280 590 280 230
0.70 175 700 330 295 650 305 265 550 260 220
0.80 200 635
300 280 590 280 255 495 235 210
0.90
225 555 260 265 530 250 235 425 200 195
NOTES − All air data is measured external to unit with1 in. foam filter (not furnished − field provided).
Air volume based on bottom air return air. Actual air volume may vary on side return air applications.
G43UF−24B−045−4 PERFORMANCE (Less Filter)
External Static
Air Volume / Watts at Different Blower Speeds
Pressure
High
Medium−High Medium−Low Low
in. w.g. Pa cfm L/s Watts cfm L/s Watts cfm L/s Watts cfm L/s Watts
0.00
0 1125 530 425 900 425 360 745 350 295 690 325 265
0.10 25 1115 525 410 905 425 350 760 360 285 695 330 260
0.20 50 1090
515 395 895 420 335 755 355 280 685 325 255
0.30
75 1060 500 380 880 415 325 740 350 270 675 320 250
0.40 100 1020 480 365 860 405 315 720 340 260 665 315 240
0.50 125 970
460 345 835 395 300 700 330 255 640 300 230
0.60
150 920 435 335 795 375 290 665 315 240 600 285 220
0.70 175 860 405 315 730 345 270 620 295 230 565 265 215
0.80 200 760
360 295 665 315 250 560 265 215 510 240 200
0.90
225 675 320 275 585 275 230 495 235 200 500 190 175
G43UF−24B−070−4 PERFORMANCE (Less Filter)
External Static
Air Volume / Watts at Different Blower Speeds
Pressure
High
Medium−High Medium−Low Low
in. w.g. Pa cfm L/s Watts cfm L/s Watts cfm L/s Watts cfm L/s Watts
0.00
0 1115 525 435 875 415 360 720 340 290 665 315 255
0.10 25 1115 525 425 865 410 350 725 340 285 670 315 255
0.20 50 1100
520 415 870 410 335 730 345 280 665 315 250
0.30
75 1080 510 400 870 410 330 725 340 270 655 310 240
0.40 100 1050 495 385 855 405 320 715 335 265 645 305 240
0.50 125 1010
475 365 835 395 310 695 330 255 625 295 230
0.60
150 980 460 355 810 380 295 675 320 250 600 285 225
0.70 175 930 440 340 770 365 285 640 300 235 565 265 215
0.80 200 855
405 320 720 340 270 585 275 220 520 245 200
0.90
225 770 365 295 650 305 250 525 245 205 465 220 190
NOTES − All air data is measured external to unit without filter (not furnished − field provided).
Air volume based on bottom air return air. Actual air volume may vary on side return air applications.