Safety engineering
Acceptance
Description
10
l
132
EDS700ACBA EN 5.1
10.3 Acceptance
10.3.1 Description
The machine manufacturer must check and prove the operability of the safety functions
used.
Inspector
The machine manufacturer must authorise a person with expertise and knowledge of the
safety functions to carry out the test.
Test report
The test result of every safety function must be documented and signed by the inspector.
) Note!
If parameters of the safety functions are changed, the inspector must repeat
the test and record the results in the test report.
Scope of test
A complete test comprises the following:
ƒ Documenting the plant including the safety functions:
Creating an overview screen of the plant
Describing the plant
Describing the safety equipment
Documenting the safety functions used
ƒ Checking the function of the safety functions used:
"Safe torque off" function, STO
ƒ Preparing the test report:
Documenting the functional test
Checking the parameters
Signing the test report
ƒ Preparing the appendix with test records:
Protocols from the plant
External recording
10.3.2 Periodic inspections
The correct sequence of the safety−oriented functions must be checked in periodic
inspections. The risk analysis or applicable regulations determine the time distances
between the tests. The inspection interval should not exceed one year.