Configuration
8-18
BA9300SU EN 2.1
Display CodeoffFAIL-QSPWar nin gMeldungTRIPMeaning
Sd5 Encoder fault at X6/1 X6/2 (C0034 = 1)
á
-
á
- • C0598
Sd6 Sensor fault: motor temperature (X7 or X8) • -
á
-
á
C0594
Sd7 Fault in the absolute value encoder at X8
á
- - - • C0025
Configuration
• Default setting
á
possible
- not possible
á
* possible, but the drive can be destroyed if the fault is not removed immediately.
8.5.4 Fault indication via digital output
In the function block DIGOUT the fault messages TRIP, message and warning can be assigned to
the digital outputs (e. g. terminals X5/A1...X5/A4).
Display TRIP or Message or Warning individually (individual indication):
1. Select digital output in the code level under C0117 and subcode.
2. Assign TRIP or Message or Warning to the parameter level.
Display TRIP, Message, Warning collectively (collective indication):
1. Assign TRIP, Message and Warning to an OR element.
2. Select digital output in the code level under C0117 and subcode.
3. Assign output of the OR-element in the parameter level.
Display monitoring functions individually:
1. Select digital output in the code level under C0117 and subcode.
2. Assign monitoring function (e.g. MONIT-OH7).