11.2.3 Digital frequency - master - drive
The most important settings (short setup)
Tip!
The following codes are contained in the menu: ”Short Setup / DF master” of the Module 9371 BB
or in the menu: ”Short commissioning / Digital frequency master” of GlobalDriveControlor LEMOC
2.
Input motor type (contains all nameplate data of the motor)
C0173 xxx Enter UG limit (mains voltage)
C0086 xxx Enter LENZE motor type
Enter maximum motor current
C0022 xxxA Determine Imax
Enter controller configuration
C0005 5000 Digital frequency - master in general
5900 with emergency stop for the drive network for QSP
C0025 xxx Enter feedback system
Speed setpoint settings
C0011 xxx rpm Determine max. speed
C0012 xxx s Set acceleration time
C0013 xxx s Set deceleration time
C0105 xxx s Set QSP deceleration time for C0005 = 5000
C0672 xxx s Set QSP deceleration time for C0005 = 59xx
C0032 xxx Gearbox factor numerator
C0033 xxx Gearbox factor denominator
C0473/1 xxx Numerator of the stretch factor
C0533 xxx Denominator of the stretch factor
Application parameters
C0070 xxx Vp n controller
C0071 xxx Tn n-controller
C0254 xxx Gain of the phase controller
Save parameters
C0003 xxx Save all parameters