Appendix
11-15
BA9300SU EN 2.1
11.3 Code table
How to read the code table:
Row Abbreviation Meaning
Code C0039
1
2
...
14
15
Code C0039
Subcode 1 of code C0039
Subcode 2 of code C0039
...
Subcode 14 of code C0039
Subcode 15 of code C0039
[C0005] Parameter value of the code can only be modified when the controller is inhibited
LCD Keypad LCD
• Display of the short text, e.g.
3$5 /2$'
Lenze Factory setting of the code
* The row ”Important” contains further information
g
Codes only display values. They cannot be configured.
Choice 1{1%}99Minimum value {smallest step/unit} maximum value
Important - Additional, important explanation of the code
Printed in bold: Code name in GDC
^
11-15 Reference to a page indicating further information on a code.
Code LCD
Possible settings
Important
C0002
3$5 /2$'
0 0 Load default Load parameter set
Load factory setting into RAM
1 Load PS1
2 Load PS2
3 Load PS3
4 Load PS4
Load parameter set x into the RAMand activate
• Parameter set1 is loaded automatically after
every mains connection.
11 Load ext PS1
12 Load ext PS2
13 Load ext PS3
14 Load ext PS4
Load parameter set x from the operating
module into the RAM and activate
20 ext -> EEPROM Transmit all parameter sets from the operating
module to the controller and store non-volatile
C0003
3$5 6$9(
0 0 Ready Save parameter set
Saving completed
1SavePS1
2SavePS2
3SavePS3
4SavePS4
Save current parameter set x non-volatile
11 Save extern Save all parameter sets to the operating
module
C0004
23',63/$<
56 All available codes Operating display
Operating module shows selected code in the
operating level if no other status indications of
C0183 are active. e