Function library
Function blocks
3.5.11 Analog signal changeover switch (ASW)
3−114
l
EDSVS9332P−EXT DE 2.0
3.5.11 Analog signal changeover switch (ASW)
Purpose
This FB changes between two analog signals.
This FB enables you to change e.g. during a winding process between an initial diameter and a
calculated diameter.
ASW1-IN1
C0812/1
1
0
C0812/2
ASW1-SET
ASW1-IN2
ASW1
ASW1-OUT
C0813
C0810/1
C0810/2
C0811
Fig. 3−69 Changeover switch for analog signals (ASW1)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
ASW1−IN1 a C0812/1 dec [%] C0810/1 1 55 −
ASW1−IN2 a C0812/2 dec [%] C0810/2 1 1000 −
ASW1−SET d C0813 bin C0811 2 1000 −
ASW1−OUT a − − − − − −
ASW2-IN1
C0817/1
1
0
C0817/2
ASW2-SET
ASW2-IN2
ASW2
ASW2-OUT
C0818
C0815/1
C0815/2
C0816
Fig. 3−70 Changeover switch for analog signals (ASW2)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
ASW2−IN2 a C0817/1 dec [%] C0815/1 1 1000 −
ASW2−IN1 a C0817/2 dec [%] C0815/2 1 1000 −
ASW2−SET d C0818 bin C0816 2 1000 −
ASW2−OUT a − − − − − −
A S W 3 - I N 1
C 1 1 6 2 / 1
1
0
C 1 1 6 2 / 2
A S W 3 - S E T
A S W 3 - I N 2
A S W 3
A S W 3 - O U T
C 1 1 6 3
C 1 1 6 0 / 1
C 1 1 6 0 / 2
C 1 1 6 1
Fig. 3−71 Changeover switch for analog signals (ASW3)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
ASW3−IN2 a C1162/1 dec [%] C1160/1 1 1000 −
ASW3−IN1 a C1162/2 dec [%] C1160/2 1 1000 −
ASW3−SET d C1163 bin C1161 2 1000 −
ASW3−OUT a − − − − − −