Function library
Function blocks
3.5.69 Variable table − speed (VTVEL)
3−281
l
EDSVS9332P−EXT DE 2.0
3.5.69 Variable table − speed (VTVEL)
One function block (VTVEL) is available.
Purpose
Stores values for traversing and final speeds. They serve as setpoint speeds in the positioning
program.
VTVEL-IN1
VTVEL
C1352/1
C1353/1
VTVEL-IN2
C1352/2
C1353/2
VTVEL-IN3
C1352/3
C1353/3
VTVEL-IN4
C1352/4
C1353/4
C1302/1
VTVEL-OUT1
C1302/2
VTVEL-OUT2
C1302/3
VTVEL-OUT3
C1302/4
VTVEL-OUT4
C1302/5
...
C1302/30
VTVEL-No 1
VTVEL-No 2
VTVEL-No 3
VTVEL-No 4
VTVEL-No 5
VTVEL-No 30
VTVEL-No 31
VTVEL-No 32
VTVEL-No 33
VTVEL-No 34
C1382/x
C1383/x
...
Fig. 3−222 Function block VTVEL
Signal
Source Note
Name Type DIS DIS format CFG List
VTVEL−IN1 ph C1353/1 dec [inc] C1352/1 3
· Generates the absolute value for negative values.
· When the values exceed vmax (C1240) the drive
moves with vmax.
VTVEL−IN2 ph C1353/2 dec [inc] C1352/2 3
VTVEL−IN3 ph C1353/3 dec [inc] C1352/3 3
VTVEL−IN4 ph C1353/4 dec [inc] C1352/4 3
VTVEL−OUT1 ph
VTVEL−OUT2 ph
VTVEL−OUT3 ph
VTVEL−OUT4 ph