EasyManuals Logo
Home>Lenze>Controller>EVS9322EP

Lenze EVS9322EP User Manual

Lenze EVS9322EP
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #176 background imageLoading...
Page #176 background image
Function library
Function blocks
3.5.20 Analog−phase converter (CONVAPH)
3−148
l
EDSVS9332P−EXT DE 2.0
3.5.20 Analog−phase converter (CONVAPH)
Conversion of an analog value into a phase signal.
CONVAPH1
CONVAPH1
CONVAPH1-OUT
C1594
CONVAPH1-IN
C1593
C1591
C1590
± 2
30
-1
Signal Source Note
Name Type DIS DIS format CFG List
CONVAPH1−IN a C1594 dec C1593 1
CONVAPH1−OUT ph Limited to ±2
30
−1
Function
l Conversion with adaptation through multiplier and divisor.
l Conversion according to formula:
CONVAPH1–OUT + CONVAPH1–IN @
C1590
C1591
@
16384
100%
CONVAPH2
CONVAPH2
CONVAPH2-OUT
C1599
CONVAPH2-IN
C1598
C1596
C1595
± 2
30
-1
Signal Source Note
Name Type DIS DIS format CFG List
CONVAPH2−IN a C1599 dec C1598 1
CONVAPH2−OUT ph Limits to ±2
30
−1
Function
l Conversion with adaptation using multiplier and divisor.
l The conversion is performed according to the formula:
CONVAPH1 * OUT + CONVAPH1 * IN @
C1595
C1596
@
16384
100%