EasyManuals Logo
Home>Lenze>Controller>EVS9322EP

Lenze EVS9322EP User Manual

Lenze EVS9322EP
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #181 background imageLoading...
Page #181 background image
Function library
Function blocks
3.5.22 Phase−analog converter (CONVPHA)
3−153
l
EDSVS9332P−EXT DE 2.0
3.5.22 Phase−analog converter (CONVPHA)
Three function blocks (CONVPHA1 ... CONVPHA3) are available.
Purpose
Conversion of a phase signal into an analog value.
CONVPHA1
CONVPHA1
CONVPHA1-OUT
C1002
± 199,99%
CONVPHA1-IN
C1001
2
C1000
1
Fig. 3−105 Function block CONVPHA1
Signal
Source Note
Name Type DIS DIS format CFG List
CONVPHA1−IN ph C1002 dec [inc] C1001 3
CONVPHA1−OUT a Limited to ±199.99 %
Function
l Conversion with adaptation using divisor.
l The conversion is performed according to the formula:
CONVPHA1–OUT + CONVPHA1–IN @
1
2
C1000
@
100%
16384
CONVPHA2
CONVPHA2
CONVPHA2-OUT
C1612
± 199,99%
CONVPHA2-IN
C1611
2
C1610
1
Fig. 3−106 Function block CONVPHA2
Signal
Source Note
Name Type DIS DIS format CFG List
CONVPHA2−IN ph C1612 dec [inc] C1611 3
CONVPHA2−OUT a Limited to ±199.99 %
Function
l Conversion with adaptation using divisor.
l The conversion is performed according to the formula:
CONVPHA2–OUT + CONVPHA2–IN @
1
2
C1610
@
100%
16384

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVS9322EP and is the answer not in the manual?

Lenze EVS9322EP Specifications

General IconGeneral
BrandLenze
ModelEVS9322EP
CategoryController
LanguageEnglish

Related product manuals