Manufacturing date
•
The manuf
acturing date is permanently stored in the device. You can read it out using
the »EASY Starter«. (Parameter 0x2000:003)
•
The manufacturing date can be found on the nameplate as well.
yyww Year of manufacture and week of
manufacture (1841 = KW 41 2018)
Addional labelling
Components of the safety technology are marked in yellow.
Stop funcons
The stop funcons include:
4Safe torque o (STO) ^ 118
4Sa
fe stop emergency (SSE) ^ 120
4Safe stop 1 (SS1) ^ 121
4Safe stop 2 (SS2) ^ 123
4Sa
fe operang stop (SOS) ^ 126
The stop funcons dier according to how they are triggered:
•
Normal stop (simple stop)
-
Triggered by the acvated bits STO, SS1 or SS2 via the safety bus.
•
Emergency stop
-
Triggered by the acvated bits SSE via the safety bus.
-
STO or SS1 can be congured as the funcon to be executed via the parameter "SSE:
Emergency stop funcon".
•
Error stop
-
Triggered as a response to an error.
•
Repair Mode Select
Funconal sa
fety
General informaon and basics
Stop funcons
110