EasyManuals Logo
Home>Lenze>Inverter>i750

Lenze i750 User Manual

Lenze i750
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #111 background imageLoading...
Page #111 background image
Priorisaon
Stop funcons with higher priority in
uence the ow of lower-order funcons which have
already been iniated.
Hierarchy:
1.
Sa
fe torque o (STO)
The funcon STO has the highest priority and hence precedence over all other
funcons.
Funcons that have already been iniated (e. g. SS1 or SS2) are aborted and the drive
is switched o.
2.
Safe stop 1 (SS1)
The funcon SS1 has priority over SS2.
Observing the dened stopping me for SS1 and SS2 as well as the SS1 mode, the drive
is rendered torqueless.
3.
Monitoring funcons
The monitoring funcons have equal priories and can be executed simultaneously
with the stop funcon.
Restart
The restart sets the drive in moon aer it w
as previously brought to a standsll via a stop
funcon.
Whether the restart needs to be acknowledged or if it launches automacally can be
parameterized in a manner dependent on the preceding stop funcon:
R
estart behavior according to STO / SS1 (0x2892:001)
Restart behavior according to SS2 / SOS (0x289F:002)
DANGER!
The requirement for the safety funcon is lied.
The driv
e may automacally restart when the requirement for the safety funcon is lied!
In the case of automac restart, you must take external measures to ensure that the drive
only restarts aer a conrmaon in accordance with EN ISO 138491.
The restart behaviour aer an emer
gency stop corresponds to that for the
restart behaviour parameterised for the stop funcon STO / SS1.
Precondions f
or restart
Seng "Ackno
wledged restart"
-
Aer a normal stop, a restart acknowledgement (AIS) via safety bus is necessary.
4Acknowledgement signals ^ 112
-
Aer a fault stop, a fault acknowledgement (AIE) is rst necessary before the restart
can be acknowledged with AIS. 4Acknowledgement signals ^ 112
AIS and AIE can also be executed via c
onrmaon dialogs in the safe parameter
list.
Seng "Aut
omac restart"
-
The drive must be in a stopped state (see status bit STO or SOS).
-
The higher-level control must ensure that the drive only restarts aer a conrmaon.
Funconal sa
fety
General informaon and basics
Priorisaon
111

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i750 and is the answer not in the manual?

Lenze i750 Specifications

General IconGeneral
BrandLenze
Modeli750
CategoryInverter
LanguageEnglish

Related product manuals