Preparaon
Aer the mechanic
al assembly, the wiring begins with making the integrated electrical
connecons.
This is how you establish the integrated DC bus connecon.
Required tools
•
Screwdriver PH 3
1.Loosen screws.
2.Turn the swivel hook into posion.
3.Tighten the screws.
The DC bus connecon from the supply module to the last inverter in the network is
established.
This is how you establish the integrated pr
otecve earth connecon.
Required tools
•
Screwdriver PH 2
1.Loosen screws.
2.Turn the swivel hook into posion.
3.Tighten the screws.
4.Double the PE connecon on the le and right product of a network in accordance with the
standard.
5.Mount the shield connecon sheet.
The protecve earth connecon from the supplier to the last inverter in the network has been
established.
Further data and in
formaon
4EMC-compliant installaon ^ 51
4St
andards and operang condions ^ 77
Electrical ins
tallaon
Preparaon
50