Funconal safety
DANGER!
Improper ins
tallaon of the safety engineering system can cause an uncontrolled starng acon of the
drives.
Possible consequence: Death or severe injuries
Safety engineering systems may only be installed and commissioned by qualied personnel.
All control components (switch, relay, PLC, ...) must comply with the requirements of EN ISO 13849−1 and
the EN ISO 13849−2.
Switches, relays with at least IP54 degree of protecon.
Always mount devices with a degree of protecon lower than IP54 in control cabinets with a minimum
degree of protecon of IP54.
The wiring must be shielded.
It is essenal to use insulated wire end ferrules for wiring.
All safety-relevant cables outside the control cabinet must be protected, e.g. by means of a cable duct.
Ensure that no short circuits can occur according to the specicaons of the EN ISO 13849−2.
All further requirements and measures can be obtained from the EN ISO 13849−1 and the
EN ISO 13849−2.
If an external force acts upon the drive axes, addional brakes are required. Please observe that hanging
loads are subject to the force of gravity!
For safety-related braking funcons, use safety-rated brakes only.
The user has to ensure that the inverter will only be used in its intended applicaon within the specied
environmental condions. This is the only way to comply with the declared safety-related characteriscs.
DANGER!
Automac r
estart if the request of the safety funcon is deacvated.
Possible consequences: Death or severe injuries
You must provide external measures according to EN ISO 13849−1 which ensure that the drive only
restarts aer a conrmaon.
NOTICE
Overvoltage
Des
trucon of the safety component
Make sure that the maximum voltage (maximum rated) at the safe inputs does not exceed 30 V DC.
NOTICE
Excessively high humidity or c
ondensaon
Malfuncon or destrucon of the safety component
Only commission the safety component when it has acclimased.
Electrical ins
tallaon
Funconal safety
166

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i950 Series and is the answer not in the manual?

Lenze i950 Series Specifications

General IconGeneral
BrandLenze
Modeli950 Series
CategoryInverter
LanguageEnglish

Related product manuals