UCX series – User's Manual 96
BAUD Rate Setting
Request and Response #rs-232 #rs232
ɯ <ip><serial_port>
ɯ body: <baudrate>
ɮ header: 200 OK
ɮ body: <baudrate>
Parameters
Parameter description Parameter values
<serial_port> Serial port number
P1-P2*
<baudrate> Baud rate value
9600
19200
38400
57600
115200
*The UCX-2x1-HC30 model has one serial port (P1).
Example
ɯ
ɯ body: 19200
ɮ header: 200 OK
ɮ body: 19200
Stop Bits Setting
Request and Response #rs232 #rs-232 #serial
ɯ <ip><serial_port>
ɯ body: <stopbits>
ɮ header: 200 OK
ɮ body: <stopbits>
Parameters
Parameter description Parameter values
<serial_port> Serial port number
P1-P2*
<stopbits> Stop bit value
1
2
*The UCX-2x1-HC30 model has one serial port (P1).
Example
ɯ
ɯ body: 1
ɮ header: 200 OK
ɮ body: 1
Request and Response
ɯ <ip><serial_port>
ɮ header: 200·OK
ɮ body: <databits>
Parameters
Parameter description Parameter values
<serial_port> Serial port number
P1-P2*
<databits> DataBits value
8
9
*The UCX-2x1-HC30 model has one serial port (P1).
Example
ɯ
ɮ header: 200 OK
ɮ body: 8
Parity Setting
Request and Response
ɯ <ip><serial_port>
ɯ body: <parity>
ɮ header: 200 OK
ɮ body: <parity>
Parameters
Parameter description Parameter values
<serial_port> Serial port number
P1-P2*
<parity> Parity value
None
Odd
Even
*The UCX-2x1-HC30 model has one serial port (P1).