Unused
VS50x mode
5.5 kW
Audio VisualAudio Visual
Unused
Ozone
Ozone and Circ Pump must be same voltage.
Do not remove Fuse F7 (20A)
12V
Light
2-Spd P1
PCBA Rev D & E only.
Black jumper required.
Do not remove.
Wiring Configuration and DIP Settings
Setup 4 (As Manufactured)
• 240V Pump 1, 2-Speed
• 120V Ozone
• 12V Spa Light
• 120V AV (Hot)
• 240V 5.5kW Heater
• Duplex Main Panel
A1, Test Mode OFF
A7, J17/26 Disabled
A2,
Mode changes allowed
A10, High Amp mode
A5, 2-speed P1
A9, Non-Circ Mode
Panel Button Assignments
1=J17/26
2=Pump 1
3=Temp
4=Light
Panel Button Positions
12 34
1
4 2
3
67
63
51
SSID #
VS50x Compatible
J12
123
Memory
Reset
J43
120 Volt Connections
240 Volt Connections
Black AC Jumpers
12 Volt Connections
Relay Control Wires
Wiring Color Key
Typically Line voltage
Typically Line voltage for 2-speed pumps
Neutral (Common)
Ground
Note flat sides in connector
Board Connector Key
1
2
3
4
WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)