OPERATING CONTROLS AND PROCEDURES 14000 OPERATOR MANUAL
3-44
Published 03-29-17, Control # 064-23
Luffing Jib Setup Mode
For current production cranes not equipped with a Luffing Jib
Limit Bypass switch, the Luffing Jib Setup Mode must be
turned on before the limits identified in Table 3-3
, Page 3-24
can be bypassed.
1. Enter the function mode in the main display
(Figure 3-30
).
2. Scroll to and enter the setup mode screen (Figure 3-31
).
3. The screen shown in Figure 3-32
will appear on display.
4. Turn the luffing jib setup mode on (or off when done with
luffing jib setup).
5. Rotate limit bypass switch (D4) clockwise and release.
The limits will remain bypassed for 10 seconds.
6. Move the desired control handle (luffing hoist, boom
hoist, load drum) in the required direction. The limits will
remain bypassed for as long as the handle is moved in
either direction.
7. The limits will remain bypassed for 10 seconds after the
control handle(s) is returned to off.
NOTE: When the luffing jib setup mode is on, the crane
setup fault is turned on and the alarm in the cab
sounds intermittently.
FIGURE 3-30
Function
Mode
Screen
FIGURE 3-31
Access the Setup
Mode Screen
FIGURE 3-32
Luffing Jib
Setup Mode
I = ON
O = OFF