Section 4 - Setup and Calibrations
90-8M0074776 eng MAY 2013 Page 27
SmartCraft
Smart contextual >
Enable
Turn on (check
mark) or off (no
checkmark)
— —
Engine running threshold > Set limit — —
Slow demand threshold > Set limit 0–99 % — —
Fast demand threshold > Set limit 0–99 % — —
Lever shift threshold > Set limit 0–99 % — —
Mode timer threshold >
Set limit 0–10.0
seconds
— —
Mode stable threshold >
Set limit 0–10.0
seconds
— —
Steady state threshold >
Set RPMs per
second
— —
Limits >
RPM, fuel rate, coolant temp,
oil temp, oil pressure, water
pressure, battery voltage,
intake temp, boost pressure,
transmission oil pressure and
temperature >
Set the limits:
minimum,
maximum, warning
low, warning high,
reset, save for
each engine.
— —
Supported data >
Location: port, port center,
starboard center, starboard >
Actual gear, boost
pressure, fuel
pressure, gear
pressure, gear
temperature, load
percent, manifold
temperature, MIL
(malfunction
indicator lamp), oil
pressure, oil
temperature,
throttle present,
water pressure
Turn on (check
mark) or off (no
checkmark)
—
Advanced > Number SmartCraft network >
1 or 2
Used with vessels
with more than 1
SmartCraft network
— —
Network number >
A or B
Used to identify the
network
— —
Easy Links
Vessels with SC 100 gauges must have the easy links enabled (check mark) in VesselView for data to be received at the SC
100 gauge.
Easy Link
Port, Starboard >
Engine and Transmission > Port or Starboard–On (checkmark), off (no checkmark)
RPM sync On (checkmark), off (no checkmark)
Fuel tank 1 On (checkmark), off (no checkmark)
Fuel tank 2 On (checkmark), off (no checkmark)
Oil tank On (checkmark), off (no checkmark)
Fresh Water On (checkmark), off (no checkmark)
Wastewater tank > Gray tank 1, Black tank 1 On (checkmark), off (no checkmark)