6.5.13 P.1
1
2
3
4
5
6
7
8
R.1.0
Maintenance Manual > Disassembly and Reassembly > Electrical Parts > Fan Motor
Model CJV30/TPC Issued 2008.08.04 Revised F/W ver. 1.00 Remark
1.0
Rev.
6.5.13 Fan Motor
Work procedures
1. Remove the following covers.
• C Y Cover F
• Cartridge Cover
• Maintenance Cover L
• Left Cover
• Left Station Cover
• Heater Connector Cover
• MS Cover 2
• MS Cover 1
2. Remove the connector of pre-heater and print heater and then
remove the platen cover R, platen C30 and platen F.
3. Remove the FAN duct V1 by lifting it obliquely.
After turning off the sub and main power switches in order, unplug the power code.
Check if no electric charge is remaining in the PCB.
Refer to the "4.5.2 Electric charge checking when replace the Electrical Parts"
It is very dangerous if sleep mode functions mistakenly during the operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also there is a possibility of electric shock because of high power voltage applied the high-pressure part
of the power supply PCB assy. Take care to avoid contact with it.
Adsorption Fan Assy
Platen C30
Platen F
FAN Duct V1

Other manuals for MIMAKI JV5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MIMAKI JV5 Series and is the answer not in the manual?

MIMAKI JV5 Series Specifications

General IconGeneral
BrandMIMAKI
ModelJV5 Series
CategoryPrinter
LanguageEnglish

Related product manuals