240
-
'16 • SCM-T-199
None
Power source system error
(Power source to indoor control PCB)
Stays OFF Stays OFF
Outdoor
Stays OFF
1. Applicable model
5. Troubleshooting
All models
Diagnosis Countermeasure
Is
AC220/240V
detected between
and
on the terminal block
of indoor
unit?
NO
NO
Are fuses
OK (F200, F201)?
YES
YES
NO
Is the
check of resistance between
-
of CNW0
OK?
NO
Is the
checked result
of resistance of FM,
LM, etc
OK?
NO
Is
AC220/240V
for 1-phase unit detected between
and on the terminal
block of outdoor
unit?
YES
YES
NO
(2)
(1)
Note (2)
for GND
Note (1) FDE, FDUM:F1, F2
Is DC5V detected
between - of CNW1
(FDTC:CNW2)?
NO
YES
YES
Is JX1 open?
YES
Defective outdoor sub PCB
(Noise lter)
Misconnection or breakage
of connecting wires
Defective indoor control or
power PCB
Replace.
Replace FM, LM, etc.
Replace fuse.
Defective indoor power
PCB
Replace.
Open JX1.
Defective indoor control
PCB
Replace.
2. Error detection method
3.
Condition of error displayed
4. Presumable cause
Misconnection or breakage of
connecting wires
Blown fuse
Faulty indoor control or
power PCB
Broken harness
Faulty outdoor sub PCB
(Noise filter)
Note:
Error code
Remote control:
LED Green Red
Indoor
Content

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SCM45ZS-S and is the answer not in the manual?

Mitsubishi SCM45ZS-S Specifications

General IconGeneral
BrandMitsubishi
ModelSCM45ZS-S
CategoryAir Conditioner
LanguageEnglish

Related product manuals