Mounting location
• Theceilingandwallmustbestrongenoughtosupportthe
monitor and mounting accessories.
• DONOTinstallinlocationswhereadoororgatecanhit
the unit.
• DONOTinstallinareaswheretheunitwillbesubjected
to strong vibrations and dust.
• DO NOT install the monitor next to a location where the
main power supply is fed into the building.
• DO NOT install the monitor in a location where people
can easily grab and hang onto the unit or the mounting
equipment.
• Allow for adequate ventilation or provide air conditioning
around the monitor, so that heat can properly dissipate
away from the monitor and from the mounting equipment.
Mounting on ceilings
• Ensurethattheceilingissturdyenoughtosupportthe
weight of the unit and the mounting equipment over time,
against earthquakes, unexpected vibrations, and other
external forces.
• Besuretheunitismountedtoasolidstructurewithin
the ceiling, such as a support beam. Secure the monitor
using bolts, spring lock washers, washer and nut.
• DONOTmounttoareasthathavenosupportinginternal
structure. DO NOT use wood screws or anchor screws for
mounting. DO NOT mount the unit to ceiling or to hanging
fixtures.
Maintenance
• Periodicallycheckforloosescrews,gaps,distortions,
or other problems that may occur with the mounting
equipment. If a problem is detected, please refer to
qualified personnel for service.
• Regularlycheckthemountinglocationforsignsof
damage or weakness that may occur over time.
Orientation
• Whenusingthemonitorintheportraitposition,itshould
be rotated clockwise so that the left side is moved to
the top, right side is moved to the bottom. This will allow
for proper ventilation and will extend the lifetime of the
monitor. Improper ventilation may shorten the lifetime of
the monitor.
LED Indicator
Changing handles position
: Factory set position.
: Alternate position.
CAUTION:
Four or more handles are required when
transporting.
V754Q
V864Q
V984Q
Changing NEC logo ornament position
When using the monitor in the portrait position, the NEC logo
ornament position can be changed.
Removing the logo ornament: unscrew the installed screw
then take off the logo ornament.
Attaching the logo ornament: make sure the holes for the
screws on the logo ornament and the holes for the screws
on the bezel are aligned. Install the logo ornament with the
screws, which are used for installing the logo ornament.
(Recommended Fasten Force: 30-40Ncm).
Screw holes
CAUTION: Do not use any other screw to install the logo
ornament.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC MultiSync V984Q and is the answer not in the manual?

NEC MultiSync V984Q Specifications

General IconGeneral
Response time8 ms
Display diagonal98 \
Display brightness350 cd/m²
Display technologyLED
Vertical scan range24 - 85 Hz
Horizontal scan range31.5 - 91.1 kHz
LED backlighting typeDirect-LED
Contrast ratio (typical)1300:1
Display number of colors1.073 billion colors
Display diagonal (metric)247.82 cm
Active display area (W x H)2158.9 x 1214.4 mm
Supported graphics resolutions1920 x 1080 (HD 1080), 1920 x 2160, 3840 x 2160, 4096 x 2160
OrientationHorizontal/Vertical
Product designDigital signage flat panel
Placement supportedIndoor
Bezel width (bottom)15.9 mm
Panel mounting interface400 x 400, 600 x 400 mm
USB version2.0
USB ports quantity5
DisplayPorts quantity3
Compatible memory cardsMicroSD (TransFlash), MicroSDHC
Ethernet LAN data rates100 Mbit/s
VGA (D-Sub) input ports0
Ethernet LAN (RJ-45) ports2
PurposeUniversal
Operating hours (hours/days)24/7
International Protection (IP) codeIP5X
Power consumption (standby)0.5 W
Power consumption (typical)380 W
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)20 - 80 %
CertificationCE; EAC; EMC B; FCC; SASO; TÜV GS; UL/C-UL, CSA; VCCI
RMS rated power20 W
Harmonized System (HS) code85285210
Weight and Dimensions IconWeight and Dimensions
Depth93 mm
Width2194 mm
Height1249 mm
Weight90000 g